List |
Item |
Limit instructions |
(a) |
IP Address or Subnet Mask Limit |
Must be composed of four numeral characters (0 to 255) and delimited with 3 dots, such as 192.168.0.253. However you cannot use the following values.
|
(b) |
Characters for the Name |
- 1 to 15 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:]
|
(c) |
Characters for Camera specific ID and Password |
- 4 to 15 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:]
- Disappear the Password when reopen the setting page after saved.
|
(d) |
Characters for Host Name, Upload File Name, and Top Page Title |
- 1 to 255 characters except following items
DHCP's Host Name: 0 to 63 characters File Name: 1 to 234 characters Top Page Title: 0 to 63 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:] except you can use the [:] for "Multi-Camera's IP Address or Host name".
|
(e) |
Characters for E-mail Address |
- Need the [@] and domain name of E-mail, such as [text] + [@] + [text] + [.] + [text].
- 5 to 63 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:]
|
(f) |
Characters for Subject and Text of Mail, and URL |
- Subject: 0 to 44 characters (In case of Notification, 0 to 63 characters), Text: 0 to 63 characters
Top Page Image URL and Link URL: 0 to 127 characters
- Cannot use the [Space], ["] except you can use the [Space] for "Subject and Text of Mail".
|
(g) |
Characters for ID and Password of FTP or E-mail |
- 0 to 63 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:]
- Disappear the Password when reopen the setting page after saved.
|
(h) |
SSID |
- 0 to 32 characters
- Cannot use the [Space], ["], ['], [#], [%], [&], [+], [?], [=], [<], [>], [:]
|
Item |
Instructions |
Limitation |
Required or Not |
1. Trigger Setting |
Please select one of the following modes.
- Capture
- Alarm
- It can buffer or transfer by alarm.
- Timer
- It can buffer or transfer by time trigger only.
Note:
- Utilizes the [Capture], when "Capture Control" is enabled in "Capture" page of "Image Transfer" menu.
- Utilizes the [Alarm], when "Alarm Control" is enabled in "Alarm" page of "Image Transfer" menu.
- Utilizes the [Timer], when "Timer Control" is enabled in "Timer" page of "Image Transfer" menu.
Caution: Buffered images are erased when Image Transfer setting page is saved. |
Select only |
- |
Trigger Setting: Capture |
- Please click the [Clear Buffered images], if you want to clear Buffered images.
|
Select only |
- |
2. Capture Control |
- If you want to disable the Start Capture of Buffered Images at Single Camera Top View Image page, please check Disable.
|
Select only |
- |
Trigger Setting: Alarm
|
- Used to buffer images or transfer images in alarm mode.
- Please click the [Clear Buffered images], if you want to clear Buffered images.
|
Select only |
- |
2. Alarm Control
|
- If you want to use Alarm trigger, please check Enable.
|
Select only |
- |
3. Active time of trigger |
|
|
|
(1) Primary Time |
- Always:
Alarm Trigger mode is always active.
- Operational between:
Operational between start and stop time, please select the desired time.
- Alarm enable condition:
Please select the [Rising] or [Falling] edge of the trigger signal.
|
Select only |
- |
(2) Secondary Time |
- Secondary Time is only active outside of the time period established for Primary Time.
- Alarm enable condition:
It can select the [Rising] or [Falling] edge of the trigger signal.
|
Select only |
- |
4. Image Setting |
Used to select the buffer image resolution and quality.
- Resolution: 640x480 / 320x240 / 160x120
- Quality: Favour Clarity / Standard / Favour Motion
|
Select only |
- |
5. Image Buffer Frequency Setting |
Selects the frequency (rate) at which buffered images are captured.
- Enable check box.
- Image Frequency:
Capture rate at which buffered images will be captured.
- Maximum number of images per each trigger:
Total buffered images are determined by memory size, image resolution/quality and target picture.
|
Select only |
- |
6. Transfer Method |
It can select the transfer method.
- Non Transfer without Memory Over Write:
Image buffering will stop the internal memory is full.
- Non Transfer with Memory Over Write:
Buffered image will overwrite the older image data when the internal memory is full.
- FTP
- Mail
|
Select only |
- |
|
- Server Address or Host Name:
Enter the proper IP address or Host Name
- Port No. (Usually Use 21):
Enter the proper Port No.
- Login ID for access to the FTP server
- Password for access to the FTP server
- Login timing:
Select the login timing.
- Upload File Name at full pass
- Over write setting:
It can select from [Over write to fix Upload File name] or [Add time stamp to Upload File name].
- Data transfer method:
Please use [Passive Mode] normally. If FTP does not work properly, please ask ISP or network administrator about the transferring mode of FTP server.
|
- (b)
- 1 to 65535
- (g)
- (g)
- Select only
- (b)
- Select only
- Select only
|
- Required when using FTP
- Required when using FTP
- -
- -
- -
- Required when using FTP
- -
- -
|
|
- SMTP Server Address or Host Name:
Enter the proper IP address or Host Name.
- POP3 Server Address or Host Name:
Enter the proper IP address or Host Name.
- Login ID for POP3 Authentication
- Password for POP3 Authentication
- From (Reply):
Enter the E-mail address of [From]. You can enter here same as [To] when you have just one E-mail address.
- To:
Enter the E-mail address of receiver of E-mail.
- Subject:
The subject of transmitting E-mail.
- Text:
The text of transmitting E-mail.
|
|
- Required when
using E-mail
- Required when
using POP3 Authentication
- Required when
using POP3 Authentication
- Required when
using POP3 Authentication
- Required when
using E-mail
- Required when
using E-mail
- -
- -
|
7. Notification to be sent when Alarm occurs |
It can select [No Message], or [Mail].
- No Message
- Mail:
It will be sent the E-mail when Alarm occurs in enable time.
|
Select only |
- |
|
Same as above [Mail setting of 6. Transfer Method], please refer to it. |
Trigger Setting: Timer |
- Selects trigger interval of buffer and transfer.
- Please click the [Clear Buffered images], if you want to clear Buffered images.
|
Select only |
- |
2. Timer Control |
- If you want to use Timer trigger, please check Enable.
|
Select only |
- |
3. Active time of trigger |
|
|
|
(1) Primary Time |
- Always:
Time Trigger mode is always active.
- Operational between:
Active only between start and stop time that's entered.
|
Select only |
- |
(2) Secondary Time |
- Secondary Time is only active outside of the time period established for Primary Time.
|
Select only |
- |
4. Image Setting
| Same as above Image Setting of [Trigger Setting: Alarm]. Please refer to it. |
5. Image Buffer Frequency Setting |
Same as above Image Buffer Frequency Setting of [Trigger Setting: Alarm]. Please refer to it. |
6. Transfer Method
| Same as above Transfer Method of [Trigger Setting: Alarm]. Please refer to it. |
|
Same as above FTP setting of [Trigger Setting: Alarm]. Please refer to it. |
|
Same as above Mail setting of [Trigger Setting: Alarm]. Please refer to it. |
<13> Restart
Restart operation takes up to 1 minute.
Caution: Buffered images are erased when you execute the restart.
<15> Reset to Factory Default
This option allows you to reset all parameters, except date and time, of Network Camera to the Factory Default.
This includes the ID, Password, IP Address and Subnet Mask.
Please refer to operation manual about Factory Default.
You can operate the "Reset to Factory Default" by
pushing the "CLEAR SETTING button" a second, located on the rear panel.
Please use a ballpoint pen or a similar object to push this button.
Caution:
- Buffered images are erased when reset to Factory Default.
- Wireless network parameters will be also set to Factory Default.